Linear Thermal Transmittance

What It Means

Linear thermal transmittance, written as the Greek letter psi (Ψ), measures the extra heat that flows along a linear thermal bridge per unit length. Common linear bridges are slab edges, parapets, window perimeters, and shelf angles. It’s expressed in W/m·K or Btu/h·ft·°F. A point thermal bridge, such as a single steel beam through the wall, uses a related value called chi (χ).

Why It Matters

Clear wall U-factors leave out the heat lost at junctions. In well insulated buildings, those junctions can make up a large share of total envelope heat loss. Psi values let designers count that loss and compare junction details before construction.

Best Practices

Real-World Use

Passive House projects routinely calculate psi values for every junction. In North America, thermal bridging catalogs give designers psi values for common slab edge, parapet, and window details, and some energy standards now include thermal bridge requirements.

Limitations

In Simple Terms

A psi value tells you how much extra heat leaks out along each meter of a junction, like the edge of a floor slab where it meets the wall.

Go Deeper

For more details, check our blogs. For how thermal continuity is maintained at transitions, see Building Envelope Control Layers and Continuity.


How D.TO Helps

As energy targets tighten, the junctions between assemblies matter more. D.TO helps teams resolve those junctions carefully and consistently across the project, so the details that drive heat loss get attention while there’s still time to improve them.

See how D.TO fits into your daily design workflow on the key features page, or schedule a demo to explore it in more detail.